Semi-annual maintenance of the PK-191 unit
Solar turbine maintenance (titan 130) of the 4000 hr (BI)
Bently Nevada vibration system maintenance
Seismic Sensor System Review: Condition, Diagnosis, and Loop Test
Bently Nevada 3500 System Monitoring
Bently nevada 3500 system review, linearity curve. Download bently nevada 3500 rack alarms and events
Decoupling HP and LP modules in GE-10 turbochargers
DESCRIPTION Dismantling of GENERAL ELECTRIC turbocharger model GE-10 COMPLETE SUCCESSFUL PROJECT 100% PROBLEM Replacement of gas turbocharger SOLUTION Decoupling of gas turbocharger PROCESS Decoupling of gas turbocharger to be replaced Disassembling auxiliary equipment and being protected.
Maintenance to lightning rod system and physical lands
DESCRIPTION Maintenance of the lightning and earthing system in the EVM combined cycle power plant 1 SUCCESSFUL COMPLETE PROJECT 100% PROBLEM Scheduled maintenance SOLUTION Maintenance of the lightning and earthing system PROCESS Maintenance of the lightning and earthing system in the EVM combined cycle power plant, performing readings and measurements as specified […]
Oviation Emerson
DESCRIPTION Emerson ovation upgrade SUCCESSFUL COMPLETE PROJECT 100% PROBLEM Scheduled upgrade SOLUTION Control system upgrade PROCESS Upgrade of OVATION distributed control system which consisted of replacing cabinets, wiring, point-to-point tests, loop tests and commissioning of the Unit
Corrective maintenance in fire-fighting system in turbochargers
The Ramones, Nuevo Leon and Camargo, Tamaulipas
System Monitoring Bently Nevada 3500
DESCRIPTION Bently nevada 3500 system monitoring PROJECT COMPLETED SUCCESSFUL 100% PROBLEM Scheduled maintenance SOLUTION Bently nevada 3500 system monitoring PROCESS Bently nevada 3500 system monitoring performing linearity curve with TK-3 equipment of 4 gas and 2 steam turbines in turn monitoring alarms and unit shots.
Major maintenance to PSV boiler valves
Guadalupe, Nuevo Leon
Replacement of thermowells/radiation shield
DESCRIPTION Replacement of thermowells/radiation shield PROJECT COMPLETED SUCCESSFUL 100% PROBLEM Damaged thermowell SOLUTION Replacement of thermowells/radiation shield PROCESS Replacement of thermowells/radiation shield applying TIG welding and performing liquid penetrants.